Set package detect input filter and sense, Write source identification message – Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual
Page 101

Interface
Chapter 7
Host Commands Using RS-232 or RS-422
7–9
Command:
IFf
Function:
When sent, this command will enable or disable the 10 msec
input filter and determine the sense of the package detect
input signal.
Response:
=rr<end>
Comments:
IF =
Set input filter command.
f =
disable or enable filter/select sense.
0 -
disable filter, LO when package is present.
1-enable filter, LO when package is present.
2-disable filter, HI when package is present.
3-enable filter, HI when package is present.
rr =
response code, refer to Table 7.B.
<end> = end of message code.
Example:
Command:
IF1
Response:
= 00CR
Comments:
1 = enable filter, LO = package.
00 = “command complete” response code.
CR = end of message control code for Carriage Return.
Command:
IMlstring
Function:
Write source code identification message.
Response:
=rr<end>
Comments:
IM = Write source identification command.
l
= length of the source identification message. Must be
from 0 to 4.
string = source identification message, up to four characters
can be specified.
rr = response code, refer to Table 7.B.
<end> = end of message control code.
7. Set Package Detect Input
Filter and Sense
8. Write Source Identification