Write no-read message – Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual

Page 106

Advertising
background image

Interface

Chapter 7
Host Commands Using the RS-232 or RS-422

7–14

Example:

Command:

MW4102041289

Response:

=00LF

Comments:

4 = match table entry number
1 = match operation enabled
02 = Interleaved 2 of 5
04 =four character code length
1289 = character string
00 = “command complete” response code
LF = end of message code for Line Feed

Command:

NC

Function:

When sent, this command will zero the no-read counter.

Response:

=rr<end>

Comments:

NC = Clear No-Read command.

rr = response code, refer to Table 7.B.

<end> = end of message code.

Example:

Command:

NC

Response:

=00CR

Comments:

00 = “command complete” response code.
CR = end of message control code for Carriage Return.

Command:

NMllstring

Function:

Write no-read message.

Response:

=rr<end>

Comments:

NM = Write no-read message command.

ll

= length of the no-read message. Must be from 00 to 32.

string = no-read message. Up to 32 characters can be
specified.

rr = response code, refer to Table 7.B.

<end> = end of message control code.

14 Write No-READ Message