Read no-read count, Set output condition and output duration – Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual
Page 107

Interface
Chapter 7
Host Commands Using RS-232 or RS-422
7–15
Example:
Command:
NM07NO-READ
Response:
=00CR
Comments:
07 = message length.
NO-READ = header message.
00 = “command complete” response code.
CR = end of message control code for Carriage Return.
Command:
NR
Function:
When sent, this command will return the count in the
no-read counter.
Response:
pppppp<end>=rr<end>
Comments:
NR = Read No-Read command.
pppppp = No-read count, up to 999999.
<end> = end of message code.
rr = response code, refer to Table 7.B.
<end> = end of message code.
Example:
Command:
NR
Response:
=000016CR=00CR
Comments:
000016 = no-read count of 16
CR = end of message control code for Carriage Return.
00 = “command complete” response code.
CR = end of message control code for Carriage Return.
Command:
OCnctttt
Function:
Sets the condition that will assert (turn on) an output and sets
the length of time in milliseconds that an output is turned on.
Response:
=rr<end>
Read No-Read Count
16. Set Output Condition and
Output Duration