Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual
Page 148

Appendix D
Configuration Areas of Memory
D–3
PCCC
Address
Configuration Parameter
Number
of Bytes
(* = Default)
Acceptable Values
42Fh
Enable Code 128
1
0 = *No
1 = Yes
430h thru 437h
Code 128 Specific Lengths
8
*0 – – – 64
438h
Enable Codabar
1
0 = *No
1 = Yes
439h thru 440h
Codabar Specific Lengths
8
*0 – – – 64
441h
Enable UPC–A
1
0 = *No
1 = Yes
442h
Enable UPC–E
1
0 = *No
1 = Yes
443h
Enable EAN–8
1
0 = *No
1 = Yes
444h
Enable EAN–13
1
0 = *No
1 = Yes
445h
Laser–On Mode
1
0 = *Continuous
1 = Triggered
446h
Decode Trigger Mode
1
0 = *Package Detect
1 = Host
2 = Internal
3 = Continuous
447h
Capture Count
1
1, *2 – – – 8
448h
Fields/Scan
1
0 = Any
1 = *1
2 = 2
3 = 3
4 = 4
449h
Fields/Package
1
*1 – – – 8
44Ah
Match Complete Count
1
*1 – – – 8
44Bh
Source Ident Length
Source Ident String
1
4
0–4, 0 = *empty
4 Characters
450h
Header Message Length
Header Message String
1
32
0–32, 0 = *empty
32 Characters
471h
No–Read Message Length
No–Read Message String
1
32
0–32, 0 = *empty
32 Characters
492h
No–Read Timer
2
*0 = Timer Disabled
0010 – – – 9999