Communications, Ac output module application, Input module auto load application – Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual
Page 22: Typical input module auto load application

Chapter 3
How the Decoder Operates
3–3
AC Output Module Application
Figure 3.3 illustrates a typical AC output module application. When using
high impedance loads, you may have to add an additional resistor (Rx) in
parallel with the load. Select a value for Rx that maintains a minimum
current of 50 mA RMS through the output module in the on state.
Figure 3.3
AC Output Module Application
AC SOURCE
Rx
DECODER
LOAD
CONNECTOR BLOCK
AC
OUTPUT MODULE
FUSE
Input Module Auto Load Application
Figure 3.4 illustrates the auto load input module application.
Figure 3.4
Typical Input Module Auto Load Application
MODULE LOCATION #8 ONLY
AC or DC SOURCE
-
+
Auto Load
Pushbutton
DECODER
CONNECTOR BLOCK
INPUT MODULE
AC or DC
FUSE
As stated earlier the decoder can transmit decoded bar code information to a
host computer or programmable controller. The three communications
Communications