Unprotected read command – Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual

Page 117

Advertising
background image

Chapter 8
Host Commands Using the RS-485 Interface

8–5

Use the unprotected read command to obtain data from the decoder’s
memory. Using this command you can “map” the memory of the decoder.
The read command is structured as follows:

00000000

00000001

TRANSACTION WORD

HI and LOW ADDRESS BYTES

SIZE OF DATA
MAXIMUM OF
124 BYTES

HI Byte

LOW Byte

UNPROTECTED READ COMMAND

Unprotected Read Command Structure

COMMAND (Byte 0) - The command byte for the unprotected read
command has the following structure.

0

0

0

0

0

0

0

1

MSB

LSB

0001 =
Unprotected
Read Command

Bit #6 Cleared
For Command

Always Set to 0

STATUS (Byte 1)- Status byte is cleared.

TRANSACTION WORD (Bytes 2 & 3)- As stated earlier, the transaction
word is provided by the host device and returned by the decoder (exactly as it
was sent) in the reply.

Unprotected Read Command