Appendix D
Configuration Areas of Memory

D–4

PCCC

Address

Configuration Parameter

Number

of Bytes

(* = Default)

Acceptable Values

494h

Inter–Scan Timer

2

*0 = Timer Disabled
0010 – – – 9999

496h

Bar Code Type in Match Code Table Entry 1

1

0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 =EAN–13
7 =Code 128

497h

Enable Match Code Table Entry 1

1

0 = *No
1 = Yes

498h

Match Code 1) Length
Match Code 1) String

1

32

0–32, 0 = *empty
32 Characters

4B9h

Output Condition 1

1

0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load

4BAh

Output Pulse 1) Duration

2

*0, 10 – – – 9999

4BCh

Bar Code Type in Match Code Table Entry 2

1

0 = *Code 38
1 = Interleaved 2 of 5
2 =Codabar
3 = UPC–A
4 =UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128

4BDh

Enable Match Code Table Entry 2

1

0 = *No
1 = Yes

4BEh

Match Code 2) Length
Match Code 2) String

1

0–32, 0 = *empty
32 Characters

4DFh

Output Condition 2

1

0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load

4E0h

Output Pulse 2) Duration

2

*0, 10 – – – 9999

Advertising