Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual
Page 149

Appendix D
Configuration Areas of Memory
D–4
PCCC
Address
Configuration Parameter
Number
of Bytes
(* = Default)
Acceptable Values
494h
Inter–Scan Timer
2
*0 = Timer Disabled
0010 – – – 9999
496h
Bar Code Type in Match Code Table Entry 1
1
0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 =EAN–13
7 =Code 128
497h
Enable Match Code Table Entry 1
1
0 = *No
1 = Yes
498h
Match Code 1) Length
Match Code 1) String
1
32
0–32, 0 = *empty
32 Characters
4B9h
Output Condition 1
1
0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
4BAh
Output Pulse 1) Duration
2
*0, 10 – – – 9999
4BCh
Bar Code Type in Match Code Table Entry 2
1
0 = *Code 38
1 = Interleaved 2 of 5
2 =Codabar
3 = UPC–A
4 =UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128
4BDh
Enable Match Code Table Entry 2
1
0 = *No
1 = Yes
4BEh
Match Code 2) Length
Match Code 2) String
1
0–32, 0 = *empty
32 Characters
4DFh
Output Condition 2
1
0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
4E0h
Output Pulse 2) Duration
2
*0, 10 – – – 9999