Communication link diagnostic commands – Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual

Page 126

Advertising
background image

Chapter 8
Host Commands Using the RS-485 Interface

8–14

You can obtain diagnostic data on the communications link (RS-485
Local-Area Network) using the diagnostic commands. The diagnostic
command has the following structure:

LINK DIAGNOSTIC COMMAND

00000000

00000110

TRANSACTION WORD

HI Byte

LOW Byte

FUNCTION CODE

DIAGNOSTIC LOOP DATA

(Only With Diagnostic Loop Command)

Link Diagnostic Command Structure

The following are descriptions of each byte in the diagnostic link command:

COMMAND (Byte 0) - The command byte for the link diagnostics
command has the following structure:

0

0

0

0

0

1

1

0

MSB

LSB

0110 = Link
Diagnostics
Command

Bit #6 Cleared
For Command

Always Set to 0

STATUS (Byte 1)- The status byte is cleared for command.

TRANSACTION WORD (Bytes 2 &3) - As with the other commands the
transaction word is a two byte code that is returned (exactly as it was sent) in
the decoder’s reply message.

Communication Link Diagnostic
Commands