Configuration Areas of Memory

PCCC

Address

Configuration Parameter

Number

of Bytes

(* = Default)

Acceptable Values

400h

Send Bar Code Data

1

0 = No
1 = *Yes

401h

Send Package Count

1

0 = *No
1 = Yes

402h

Send Bar Code Type

1

0 = *No
1 = Yes

403h

Send Source Ident

1

0 = *No
1 = Yes

404h

Send Header Message

1

0 = *No
1 = Yes

405h

Send No–Read Message

1

0 = *No
1 = Yes

406h

Expand UPC–E

1

0 = No
1 = *Yes

407h

Label Delimiter

1

ASCII 0–255, 255 = *None

408h

Start Character

1

ASCII 0–255, 255 = *None

409h

End Message

1

0 = None
1 = *CRLF
2 = CR
3 = LF
4 = ETX

40Ah

Transmission Check

1

0 = *None
1 = LRC
2 = Checksum–LSB
3 = Checksum–MSB

40Bh

Code 39 Check Char

1

0 = *No
1 = Yes

40Ch

Send Code 39 Check Char

1

0 = *No
1 = Yes

40Dh

I 2–of–5 Check Char

1

0 = *No
1 = Yes

40Eh

Send I 2–of–5 Check Char

1

0 = *No
1 = Yes

40Fh

Codabar Check Char

1

0 = *No
1 = Yes

410h

Send Codabar Check Char

1

0 = *No
1 = Yes

Advertising