D - configuration areas of memory – Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual
Page 146

A–B
D
Appendix
D–1
Configuration Areas of Memory
PCCC
Address
Configuration Parameter
Number
of Bytes
(* = Default)
Acceptable Values
400h
Send Bar Code Data
1
0 = No
1 = *Yes
401h
Send Package Count
1
0 = *No
1 = Yes
402h
Send Bar Code Type
1
0 = *No
1 = Yes
403h
Send Source Ident
1
0 = *No
1 = Yes
404h
Send Header Message
1
0 = *No
1 = Yes
405h
Send No–Read Message
1
0 = *No
1 = Yes
406h
Expand UPC–E
1
0 = No
1 = *Yes
407h
Label Delimiter
1
ASCII 0–255, 255 = *None
408h
Start Character
1
ASCII 0–255, 255 = *None
409h
End Message
1
0 = None
1 = *CRLF
2 = CR
3 = LF
4 = ETX
40Ah
Transmission Check
1
0 = *None
1 = LRC
2 = Checksum–LSB
3 = Checksum–MSB
40Bh
Code 39 Check Char
1
0 = *No
1 = Yes
40Ch
Send Code 39 Check Char
1
0 = *No
1 = Yes
40Dh
I 2–of–5 Check Char
1
0 = *No
1 = Yes
40Eh
Send I 2–of–5 Check Char
1
0 = *No
1 = Yes
40Fh
Codabar Check Char
1
0 = *No
1 = Yes
410h
Send Codabar Check Char
1
0 = *No
1 = Yes