Appendix A
Setting Up the Programming Terminal
A–3
The Catalog No. 1784-T45 Programming Terminal may be used to program
the 2755-DM9, -DM9E decoder. Set the T45 Terminal Emulation to the
following:
•
F1DGC D200 Terminal
•
F2Modem = External
•
F3Flow Control = On
•
F4Duplex = Full
•
F6Print = Off
Set the COM 1 parameters to:
•
F1Baud = 9600
•
F2Parity = None
•
F3Data Bits = 8
•
F4Stop Bits = 1
•
F5Type = Standard PC Compatible Com
Note: If an internal modem is being used, it must be disabled using the
MODE command.
Fabricate the cable shown in Figure A.4.
Figure A.4
Connections for Cable Used with 1784-T45 Terminal
•
DTR
CD
DSR
CTS
AUX Port on Decoder-DCE
Note
:
Connect shield to shell of
cable connectors at both ends.
2
3
7
2
3
Transmit Data
Receive Data
Cable:
Belden 9939 or
equivalent
7
8
20
RTS
1784-T45-DTE Device
With DG D200 emulation.
6
5
4
Signal Ground
When the
Select CRT Type
menu appears, select Data General D200
emulation.
Using a Catalog Number
1784-T45 Terminal for
Programming