Chapter 8
Host Commands Using the RS-485 Interface

8–3

COMMAND (Byte 0) - The first byte indicates one of the following
commands:

Unprotected Read

Diagnostic

Unprotected Write

The command byte has the following structure:

Bits 7, 5, and 4 are always zero.

Bit 6 is cleared (0) for command, set (1) for reply.

Bits 0, 1, 2, and 3 contain the command code:
0001 = Unprotected Read
0110 = Diagnostic
1000 = Unprotected Write

Example: To send an unprotected write command the following data would
be sent as byte 0:

0

0

0

0

1

0

0

0

MSB

LSB

1000 =
Unprotected
Write Command

Bit #6 Cleared
For Command

Always Set to 0

STATUS (Byte 1)- The second byte of a command indicates the status code
of any command response:

Bits 0 through 3 are reserved for local status codes.

Bits 4 through 7 are for remote status codes.

Note: Since the decoder does not implement local status codes, bits 0
through 3 are always cleared (set at 0).