Chapter 8
Host Commands Using the RS-485 Interface

8–10

the decoder’s memory where the host can write data (addresses are provided
in hexadecimal):

1) Configuration Block- Address 400 to 5FF. Refer to Appendix D for
addresses of specific configuration data.

2) Command Area- 600 to 6FF. Writing to the command area will initiate a
command. Table 8.C lists the commands that can be initiated.

Address

(Hex)

Function

Address

(Hex)

Function

600

Clear Package Counter.

630

Clear All Match Counters.

604

Clear Output Counter 1.

631

Clear All Counters.

608

Clear Output Counter 2.

632

Save Configuration to EEPROM.

60C

Clear Output Counter 3.

633

Set Configuration to Default Values.

610

Clear Output Counter 4.

634

Start Scan Trigger.

614

Clear Output Counter 5.

635

Stop Scan Trigger.

618

Clear Output Counter 6.

636

Flush Host Buffer.

61C

Clear Output Counter 7.

637

Restart.

620

Clear Output Counter 8.

640

Repeat Read (See page 8-13).

624

Clear No-Read Counter

.

641

Cancel Repeat Read (See page 8-13).

DATA (Bytes 6 through 127)- These bytes contain the data that is to be
written into memory (up to 122 bytes).

Unprotected Write Reply Format

The decoder’s reply to a write command has the following structure:

UNPROTECTED WRITE REPLY

STATUS

01001000

TRANSACTION WORD

HI Byte

LOW Byte

The following are descriptions of each byte in the write reply message:

REPLY (Byte O)- The command reply byte has the following structure.

Advertising