Chapter 4
Configuring Your Decoder

4–39

3) Press the key which corresponds to your programming terminal. After
specifying the CRT type, the following will be displayed:

2755-DM9 Bar Code Reader VX.XX
Copyright 1990 Allen-Bradley Company, Inc.

SELECT OPERATION

1) Display Bar Code Labels
2) Display Status and Counters
3) Display/Change Configuration
4) Reset Status and Counters
5) Restart
6) Select Language

Press 1, 2, 3, 4, 5, 6, or ESC

4) Press the [3] key to select the Display/Change Configuration operation.
The following will be displayed:

CAUTION

Configuration changes may cause the discrete outputs to switch.

If outputs are to remain ENABLED, press ESC.

Otherwise press any other key to continue. Outputs
will be DISABLED until the device is restarted.

Note: We recommend that the outputs be DISABLED during configuration
to prevent unintentional switching. The outputs can be ENABLED by
performing a Restart after configuration (remember to SAVE changes to
EEPROM before Restarting.