Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual
Page 152

Appendix D
Configuration Areas of Memory
D–7
PCCC
Address
Configuration Parameter
Number
of Bytes
(* = Default)
Acceptable Values
57Ah
Bar Code Type in Match Code Table Entry 7
1
0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128
57Bh
Enable Match Dode Table Entry 7
1
0 = *No
1 = Yes
57Ch
Match Code 7) Length
Match Code 7) String
1
32
0–32, 0 = *empty
32 Characters
59Dh
Output Condition 7
1
0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
59Eh
Output Pulse 7) Duration
2
*0, 10 – – – 9999
5A0h
Bar Code Type in Match Code Table Entry 8
1
0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128
5A1h
Enable Match Code Table Entry 8
1
0 = *No
1 = Yes
5A2h
Match Code 8) Length
Match Code 8) String
1
32
0–32, 0 = *empty
32 Characters
5C3h
Output Condition 8
1
0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
8 = Auto Load (INPUT)
5C4h
Output Pulse 8) Duration
2
*0, 10 – – – 9999
5C4h
Last Valid Address in Configuration Area