Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual

Page 152

Advertising
background image

Appendix D
Configuration Areas of Memory

D–7

PCCC

Address

Configuration Parameter

Number

of Bytes

(* = Default)

Acceptable Values

57Ah

Bar Code Type in Match Code Table Entry 7

1

0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128

57Bh

Enable Match Dode Table Entry 7

1

0 = *No
1 = Yes

57Ch

Match Code 7) Length
Match Code 7) String

1

32

0–32, 0 = *empty
32 Characters

59Dh

Output Condition 7

1

0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load

59Eh

Output Pulse 7) Duration

2

*0, 10 – – – 9999

5A0h

Bar Code Type in Match Code Table Entry 8

1

0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128

5A1h

Enable Match Code Table Entry 8

1

0 = *No
1 = Yes

5A2h

Match Code 8) Length
Match Code 8) String

1

32

0–32, 0 = *empty
32 Characters

5C3h

Output Condition 8

1

0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
8 = Auto Load (INPUT)

5C4h

Output Pulse 8) Duration

2

*0, 10 – – – 9999

5C4h

Last Valid Address in Configuration Area

Advertising