Chapter 4
Configuring Your Decoder

4–16

Reference

Letter

Description

Field

Type

Options (Select Field

Only)

Valid Entries (Edit Field

Only)

u

Host port–baud rate.

Select

300, 1200, 2400, 4800,
9600, 19200, 38400

N/A

v

Host port–number of data and stop bits.

Select

8 data, 1 stop
8 data, 2 stop
7 data, 1 stop
7 data, 2 stop

N/A

w

Host port–parity.

Select

None, Odd, or Even

N/A

x

Host port–ACK character.

Edit

N/A

Numeric ASCII code ( 0 to
255) 255 = None.

y

Host Port–NAK character.

Edit

N/A

Numeric ASCII code ( 0 to
255) 255 = None.

z

Host port–start scan character.

Edit

N/A

Numeric ASCII code ( 0 to
255) 255 = None.

aa

Host port–stop scan character.

Edit

N/A

Numeric ASCII code ( 0 to
255) 255 = None.

bb

Enable host port buffer (8k bytes).

Select

Yes or No

N/A

cc

Response mode.

Select

End of Trigger, or After
Valid Package.

N/A

dd

Host protocol.

Select

RS232 No flow control
RS232 XON/XOFF
RS232 RTS/CTS–1

RS232 RTS/CTS–2

RS422 No flow control
RS422 XON/XOFF
RS485 PCCC–1
PCCC with write
replies
RS485 PCCC–2
PCCC without write
replies
RS485 ASCII–1 ASCII
Commands with
command responses
RS485 ASCII–2 ASCII
Commands without
command responses

N/A

ee

Device address for Class 1 node.

Edit

N/A

00 through 31

ff

Enable package detect filter.

Select

Yes or No

N/A

gg

Package detect polarity (sense).

Select

LO = Package
HI = Package

N/A

Refer to Chapter 6 for a description of the RS-232 modes 3 and 4. Both of these modes use the modem control lines (RTS, CTS and DTR). However, there are differences in

how these control lines are used.

Refer to Appendix C for ASCII conversion chart.