Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual

Page 151

Advertising
background image

Appendix D
Configuration Areas of Memory

D–6

PCCC

Address

Configuration Parameter

Number

of Bytes

(* = Default)

Acceptable Values

52Eh

Bar Code Type in Match Code Table Entry 5

1

0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128

52Fh

Enable Match Code Table Entry 5

1

0 = *No
1 = Yes

530h

Match Code 5) Length
Match Code 5) String

1

32

0–32, 0 = *empty
32 Characters

551h

Output Condition 5

1

0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load

552h

Output Pulse 5) Duration

2

*0, 10 – – – 9999

554h

Bar Code Type in Match Code Table Entry 6

1

0 = *Code 39
1 = Interleaved 2 of 5
2 =Codabar
3 = UPC–A
4 = UPC–E
5 =EAN–8
6 =EAN–13
7 = Code 128

555h

Enable Match Code Table Entry 6

1

0 = *No
1 = Yes

556h

Match Code 6) Length
Match Code 6) String

1

32

0–32, 0 = *empty
32 Characters

577h

Output Condition 6

1

0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load

578h

Output Pulse 6) Duration

2

*0, 10 – – – 9999

Advertising