Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual

Page 147

Advertising
background image

Appendix D
Configuration Areas of Memory

D–2

PCCC

Address

Configuration Parameter

Number

of Bytes

(* = Default)

Acceptable Values

411h

Host Port - Baud Rates (READ–ONLY)

1

0 = *9600
1 = 4800
2 = 2400
3 = 1200
4 = 300
5 = 19200
6 = 38400

412h

Host Port - Stop Bits (READ–ONLY)

1

0 = *8 data, 1 stop
1 = 8 data, 2 stop
2 = 7 data, 1 stop
3 = 7 data, 2 stop

413h

Host Port - Parity (READ–ONLY)

1

0 = *None
1 = Odd
2 = Even

414h

Host Port - ACK Character

1

ASCII 0–255, 255 = *None

415h

Host Port - NAK Character

1

ASCII 0–255, 255 = *None

416h

Start Scan Character

1

ASCII 0–255, 255 = *None

417h

Stop Scan Character

1

ASCII 0–255, 255 = *None

418h

Enable Large Buffer

1

0 = *No
1 = Yes

419h

Response Mode

1

0 = *End of Trigger
1 = After Valid Package

41Ah

Host Protocol (READ–ONLY)

1

0 = *RS232
1 = RS232 XON/XOFF
2 = RS232 RTS/CTS–1
3 = RS232 RTS/CTS–2
4 = RS422
5 = RS422 XON/XOFF
6 = RS485 PCCC–1
7 = RS485 PCCC–2
8 = RS485 ASCII–1
9 = RS485 ASCII–2

41Bh

Device Address (READ–ONLY)

1

00, *01 – – – 31

41Ch

Enable Input Filter and Set Sense of Package
Detect Input

1

0 = *No Filter, LO = Package
1 = Filter (15 msec), LO =
Package
2 = No Filter, HI = Package
3 = Filter (15 msec), HI =
Package

41Dh

Enable Code 39

1

0 = No
1 = *Yes

41Eh thru

425h

Code 39 Specific Lengths

8

*0 – – – 64

426h

Enable Interleaved 2 of 5

1

0 = *No
1 = Yes

427h thru

42Eh

I 2–of–5 Specific Lengths

8

*0 – – – 64
(Must be even)