Rockwell Automation 20L, LPM20 PowerFlex 700 Active Converter Power Module User Manual

Page 20

Advertising
background image

2-2

Start Up

PowerFlex 700L Active Converter Power Module User Manual

Publication PFLEX-UM002D-EN-P

3. The HIM displays that it is currently communicating with the Inverter on

DPI Port 0.

4. Press the Down arrow to scroll to “PowerFlex 700 AC.”

5. With “PowerFlex 700 AC” highlighted as shown in Step 4, press the

Enter key to start communicating with the Active Converter on DPI Port
6.

To examine the fault queue in the Active Converter, press the Up

Arrow to scroll to “Diagnostics” and press the Enter key.

To begin examining parameters (with “Parameters” highlighted),

press the Enter key.

To resume communication with the Inverter, press the Down Arrow to

scroll to “Device Select” and press the Enter key.

6. After accessing the Parameter menu, the display shows the File menu.

Press the Up or Down Arrow to select the desired file and press the Enter
key.

F->

Stopped

Auto

0.0

RPM

Device: Port

0

PowerFlex 700S 2

PowerFlex 700 AC

F->

Stopped

Auto

0.0

RPM

Device: Port

6

PowerFlex 700S 2

PowerFlex 700 AC

Port 6 Device

PowerFlex 700AC

Main Menu:

Diagnostics

Parameter

Device Select

Port 6 Device

PowerFlex 700AC

F

GP: File

Monitor

Command
Limit Config