Summary of changes – Rockwell Automation 20L, LPM20 PowerFlex 700 Active Converter Power Module User Manual

Page 3

Advertising
background image

PowerFlex 700L Active Converter Power Module User Manual

Publication PFLEX-UM002D-EN-P

Summary of Changes

The information below summarizes the changes resulting from the firmware
v3.001 upgrade to this manual since its last release (June, 2006):

Description of New or Updated Information

Page(s)

To all pages, added a new footer containing:

Publication description (1st line).

Publication number hyperlink underlined in blue (2nd line) linking to the date of the
publication on the back cover.

The back cover publication date line hyperlinks to the newest version of the publication
on Rockwell Automation’s Literature Library web site.

Throughout
Manual

Added new information about the Active Converter operating as a Coupled unit (DPI
SLAVE) or as a Stand Alone unit (DPI MASTER).

1-6

Changed the following for Parameter 051 - [Option Select]:

Bit 6 changed from “Reserved” to “VC Inverter.”

Bit 7 changed from “Reserved” to “Prechg Cntrl.”

The default changed from “xxxx xxxx xx00 0001” to “xxxx xxxx 0000 0001.”

3-6

Added new Parameter 105 - [Regen I Lmt].

3-9

Changed Parameter 153 - [CML Bandwidth] maximum value from “3000 Rad/sec” to
“4000 Rad/sec.”

3-11

Changed the description for Parameter 157 - [PF Bandwidth] to include that it should be
used only when unbalanced voltage compensation is enabled in Parameter 051 -
[Option Select].

3-11

Changed Parameter 162 - [Capacitance] maximum value from “32767 µF” to “65535 µF.”

3-12

Added new Parameter 170 - [Bus Capacitance].

3-12

Added new Bit 11 (High DC Link) to Parameter 214 - [Start Inhibit].

3-14

Changed Parameter 238 - [Fault Config] default from “xxxx xxx1 1110 1100” to
“xxxx xxx1 0110 1100.”

3-15

Added two new parameter groups which are only displayed and available in the
Communication File when the Converter is operated as a Stand Alone unit:

Masks and Owners Group

– Parameter 340 - [Logic Mask]
– Parameter 341 - [Start Mask]
– Parameter 342 - [Fault Clr Mask]
– Parameter 343 - [Stop Owner]
– Parameter 344 - [Start Owner]
– Parameter 345 - [Fault Clr Owner]

Security Group

– Parameter 346 - [Port Mask Act]
– Parameter 347 - [Write Mask Cfg]
– Parameter 348 - [Write Mask Act]
– Parameter 349 - [Logic Mask Act]

3-18

Added the following new fault codes:

70 – FiltCap Contactr

71 – Port 1 Adapter

72 – Port 2 Adapter

73 – Port 3 Adapter

74 – Port 4 Adapter

75 – Port 5 Adapter

76 – Port 6 Adapter

81 – Port 1 DPI Loss

82 – Port 2 DPI Loss

83 – Port 3 DPI Loss

84 – Port 4 DPI Loss

85 – Port 5 DPI Loss

86 – Port 6 DPI Loss

4-3

Advertising