Hapter, Mechanical/electrical description, 1 status led – Rockwell Automation GV3000/SE, VTAC 7 Super Remote Meter Interface Board M/N 2SI3000 M/N 2SI3000E User Manual

Page 11

Advertising
background image

Mechanical/Electrical Description

2-1

C

HAPTER

2

Mechanical/Electrical Description

The optional RMI board is a printed circuit assembly that mounts inside the drive. It
connects to the Regulator board through a flexible ribbon cable and is powered by the
drive power supply. Refer to figure 2.1 for the RMI board layout. This figure also shows
the factory-set jumper positions.

2.1

Status LED

The green LED on the RMI board indicates the status of the RMI board and the
communications link between the RMI board and the drive.

Figure 2.1 – RMI Board

5HJXODWRU %RDUG 5LEERQ

&DEOH &RQQHFWRU

6WDWXV /('

2.

,17

(;7

'LJLWDO 2XWSXWV 6XSSO\

'HIDXOW ,QWHUQDO  9

5HOD\V

$QDORJ ,QSXW

'HIDXOW  9

$QDORJ 2XWSXW 

'HIDXOW  9

9 ,1
& ,1

9 287

& 287

;

;

7HUPLQDO 6WULS

01 6, ERDUG SURYLGHV VFUHZ WHUPLQDOV 1RW LQWHQGHG IRU XVH LQ *96( %RRNVKHOI GULYHV

01 6,( ERDUG SURYLGHV VSULQJORDGHG WHUPLQDOV

If the LED is …

It indicates that …

On

Power-up diagnostics are complete and no fault has been
detected.

Flashing

The RMI board and the drive are communicating.

Off

The drive is not powered up or a fault has been detected on the
RMI board. See chapter 5 for a list of fault codes. (Note that the
LED will be off during a reset and during power up.)

Advertising