Installation

3-33

Step 3.1 Record connections to the Regulator board terminal strip if they must be

disconnected to remove the keypad bracket.

Step 3.2 Use a magnetic screwdriver to remove the four screws and lock washers

that fasten the keypad bracket to the hinged mounting panel. Hold the
keypad bracket as you remove the screws.

Step 3.3 Disconnect the Regulator board ribbon cable from the Power Module

Interface board.

Step 4.

Install the RMI Board

Step 4.1 Remove the RMI board from its anti-static wrapper and verify that the

jumper settings are correct. Refer to figure 2.1 for jumper locations and
appendix A for jumper settings.

The RMI board mounts on four standoffs behind the Regulator board.

Step 4.2 Align the RMI board’s four mounting holes with the four standoffs on the

hinged mounting panel of the drive.

Step 4.3 Fasten the board to the drive with four

nuts. Metal nuts must be used

for proper grounding of the RMI board.

Step 4.4 Connect the RMI wiring to the appropriate RMI terminals for your

application. Refer to section 3.9 for terminal identification. Route the wiring
through the signal wiring tray on the right side of the drive.

Step 4.5 Align the key on the Regulator board’s 34-conductor ribbon cable connector

with the slot in the RMI board’s connector. Press the ribbon cable connector
in until it locks into position.

Step 5.

Reinstall the Keypad Bracket in the Drive

Step 5.1 Align the key on the connector from the Regulator board with the key of the

connector on the Power Module Interface board. Press the ribbon cable
connector in until it locks into position.

Step 5.2 Reconnect the keypad bracket to the hinged mounting panel using the four

screws removed earlier.

Step 5.3 Reconnect any wiring that was removed from the Regulator board terminal

strip. Refer to the terminal connections documented in step 3.1 or to the
appropriate instruction manuals for the devices being used.

Step 5.4 Close and secure the outer cabinet door of the drive.

Step 5.5 Remove the lockout and tag. Apply power to the drive. SELF will be

displayed while the drive performs power-up diagnostics.

This completes the hardware installation of the RMI board. Refer to chapter 4 for the
required software parameter settings for your drive.

!

ATTENTION: The RMI board contains components that are
static-sensitive. An anti-static wrist band should be worn by any person
who touches the board’s components, connectors, or wiring. Failure to
observe this precaution could result in damage to the RMI board.