Installation
3-33
Step 3.1 Record connections to the Regulator board terminal strip if they must be
disconnected to remove the keypad bracket.
Step 3.2 Use a magnetic screwdriver to remove the four screws and lock washers
that fasten the keypad bracket to the hinged mounting panel. Hold the 
keypad bracket as you remove the screws.
Step 3.3 Disconnect the Regulator board ribbon cable from the Power Module
Interface board.
Step 4.
Install the RMI Board
Step 4.1 Remove the RMI board from its anti-static wrapper and verify that the
jumper settings are correct. Refer to figure 2.1 for jumper locations and 
appendix A for jumper settings.
The RMI board mounts on four standoffs behind the Regulator board.
Step 4.2 Align the RMI board’s four mounting holes with the four standoffs on the
hinged mounting panel of the drive.
Step 4.3 Fasten the board to the drive with four
″
nuts. Metal nuts must be used
for proper grounding of the RMI board.
Step 4.4 Connect the RMI wiring to the appropriate RMI terminals for your
application. Refer to section 3.9 for terminal identification. Route the wiring 
through the signal wiring tray on the right side of the drive.
Step 4.5 Align the key on the Regulator board’s 34-conductor ribbon cable connector
with the slot in the RMI board’s connector. Press the ribbon cable connector 
in until it locks into position.
Step 5.
Reinstall the Keypad Bracket in the Drive
Step 5.1 Align the key on the connector from the Regulator board with the key of the
connector on the Power Module Interface board. Press the ribbon cable 
connector in until it locks into position.
Step 5.2 Reconnect the keypad bracket to the hinged mounting panel using the four
screws removed earlier.
Step 5.3 Reconnect any wiring that was removed from the Regulator board terminal
strip. Refer to the terminal connections documented in step 3.1 or to the 
appropriate instruction manuals for the devices being used.
Step 5.4 Close and secure the outer cabinet door of the drive.
Step 5.5 Remove the lockout and tag. Apply power to the drive. SELF will be
displayed while the drive performs power-up diagnostics.
This completes the hardware installation of the RMI board. Refer to chapter 4 for the 
required software parameter settings for your drive.
!
ATTENTION: The RMI board contains components that are 
static-sensitive. An anti-static wrist band should be worn by any person 
who touches the board’s components, connectors, or wiring. Failure to 
observe this precaution could result in damage to the RMI board.
7
32
⁄