Installation

3-21

3.5

Installing the RMI Board in 15 to 25HP and
25 to 60HP @ 460VAC Drives

Use this procedure to install the RMI board in the drives listed in table 3.6.

Unless otherwise indicated, keep all hardware that is removed. You will need it for
reassembly. This includes screws, lock washers, and rivets.

If the drive is panel-mounted, this procedure will be easier to perform if the drive is
removed from the panel.

Important: Read and understand the warning labels on the outside of the drive

before proceeding.

!

ATTENTION: Only qualified electrical personnel familiar with the
construction and operation of this equipment and the hazards involved
should install, adjust, operate, or service this equipment. Read and
understand this manual and other applicable manuals in their entirety
before proceeding. Failure to observe this precaution could result in
severe bodily injury or loss of life.

ATTENTION: The drive is at line voltage when connected to incoming
AC power. Disconnect, lock out, and tag all incoming power to the drive
before performing the following procedure. Failure to observe this
precaution could result in severe bodily injury or loss of life.

ATTENTION: DC bus capacitors retain hazardous voltages after input
power has been disconnected. After disconnecting input power, wait five
minutes for the DC bus capacitors to discharge and then check the
voltage with a voltmeter to ensure the DC bus capacitors are discharged
before touching any internal components. Failure to observe this
precaution could result in severe bodily injury or loss of life.

ATTENTION: The drive contains printed circuit boards that are
static-sensitive. An anti-static wrist band should be worn by any person
who touches the drive’s components, connectors, or wiring. Erratic
machine operation and damage to, or destruction of, equipment can
result if this procedure is not followed. Failure to observe this precaution
could result in bodily injury.

Table 3.6 – Model Numbers for 15 to 25HP and 25 to 60HP @ 460VAC Drives

15 to 25 HP

25 to 60 HP

GV3000

VTAC 7

GV3000

VTAC 7

15V41xx
15V42xx

15H41xx
15H42xx

25V41xx
25V42xx

25W21xx

20V41xx
20V42xx

20H41xx
20H42xx

30V41xx
30V42xx

30H41xx
30H42xx

25G41xx
25G42xx

25H41xx
25H42xx

40V41xx
40V42xx

40H41xx
40H42xx

50V41xx
50V42xx

50H41xx
50H42xx

60G41xx
60G42xx

60H41xx
60H42xx

Advertising