Super Remote Meter Interface (RMI) Board

r.025 Torque or Current Limit Selection

(Continued)

The four digital inputs on the RMI board expand the options for the speed reference
selection. Parameter r.030 configures the digital inputs, similar to the way P.007
configures the terminal strip inputs on the Regulator board.

Note that to use the RMI speed reference, P.000 must be set to remote (rE). If P.000 is
set to option (OP) and an RMI board is used, the speed reference will be zero.

Figure 4.3 – Torque or Current Limit Selection

7RUTXH

/LPLW

&XUUHQW

/LPLW



$QDORJ ,QSXW

)UHTXHQF\ ,QSXW







U

9HFWRU

9+]

r.030 Digital Input Configuration

Par.

Parameter Name

Type

Default

Step

Range

r.030

Digital Input Configuration

Config.

0

1

0 to 8 (Table 4.3)

Table 4.3 – Digital Input Configuration Selections for r.030

r.030

Digital Input 1

(DIGIN 1)

Digital Input 2

(DIGIN 2)

Digital Input 3

(DIGIN 3)

Digital Input 4

(DIGIN 4)

0 =

Reference 1 / 2

Analog / Freq

Aux Input 2

Aux Input 1

1 =

Reference 1 / 2

Analog / Freq

Aux Input 2

PI-Enable

2 =

Reference 1 / 2

MOP

MOP

Aux Input 1

3 =

Reference 1 / 2

MOP

MOP

PI-Enable

4 =

Reference 1 / 2

2 Presets

Aux Input 2

Aux Input 1

5 =

Reference 1 / 2

2 Presets

Aux Input 2

PI-Enable

6 =

Reference 1 / 2

4 Presets

4 Presets

Aux Input 1

7 =

Reference 1 / 2

4 Presets

4 Presets

PI-Enable

8 =

Reference 1 / 2

8 Presets

8 Presets

8 Presets