Dell PowerEdge C8000 User Manual
Page 185

Installing System Components
185
2 Install the interposer extender. See "Installing the Interposer Extender" on
3 Install the rear hard-drives. See "Installing a Hard-Drive Carrier on the
4 Install the sled cover.
a
Orient the sled cover such that the card riser connector is directly
above the connector on the system board and press gently to seat the
card riser connector. See Figure 3-28.
b
Firmly press down the sled cover to ensure it is completely seated.
Make sure the twin axial cable is tucked inside. See Figure 3-28.
c
Secure the sled cover to the sled tray using four crews.
NOTE:
Make sure the twin axial cable do not protrude from the opening on the
sled.
5 Connect the emergency throttling cables.
a
Connect the 4-pin emergency throttling cable labeled Base PS_ON to
the node power distribution board on the sled tray. See Figure 3-30.
b
Make sure the 2-pin emergency throttling cable labeled Top PS_ON is
connected to the node power distribution board on the sled cover.