Sled hard-drive leds – Dell PowerEdge C8000 User Manual

Page 28

Advertising
background image

28

About Your System

* This condition is not supported in LSI HBA/RAID cards. When you abort the RAID rebuild process,
the hard-drive LED blinks amber to indicate drive failure.
This LED pattern is not applicable for the non-RAID mode of onboard SATA, for example, without Intel
RSTe drivers.

Sled Hard-Drive LEDs

The hard-drive LEDs located on the front of the C8220X sled alerts you to

the condition of the hard-drives in the sled.

Figure 1-9. Sled Hard-Drive LEDs

Drive rebuilding

aborted*

Off/Blinking when active

On 3000 ms
Off 9000 ms

Off 6000 ms
On 3000 ms
Off 3000 ms

Condition

Hard-Drive LEDs

(HDD0 to HDD7)

Green LED

Amber LED

Drive bay empty/Unsupported drive is present

Off

Off

Drive online/access

On

Off

Drive identify/Preparing for removal

On 250 ms
Off 250 ms

Off

Drive rebuilding

On 400 ms
Off 100 ms

Off

Drive failed

Off

On 150 ms
Off 150 ms

Condition

Hard-Drive Activity LED

Hard-Drive Status LED

Green LED

Green LED

Amber LED

Advertising