Sled hard-drive leds – Dell PowerEdge C8000 User Manual
Page 28
28
About Your System
* This condition is not supported in LSI HBA/RAID cards. When you abort the RAID rebuild process,
the hard-drive LED blinks amber to indicate drive failure.
This LED pattern is not applicable for the non-RAID mode of onboard SATA, for example, without Intel
RSTe drivers.
Sled Hard-Drive LEDs
The hard-drive LEDs located on the front of the C8220X sled alerts you to
the condition of the hard-drives in the sled.
Figure 1-9. Sled Hard-Drive LEDs
Drive rebuilding
aborted*
Off/Blinking when active
On 3000 ms
Off 9000 ms
Off 6000 ms
On 3000 ms
Off 3000 ms
Condition
Hard-Drive LEDs
(HDD0 to HDD7)
Green LED
Amber LED
Drive bay empty/Unsupported drive is present
Off
Off
Drive online/access
On
Off
Drive identify/Preparing for removal
On 250 ms
Off 250 ms
Off
Drive rebuilding
On 400 ms
Off 100 ms
Off
Drive failed
Off
On 150 ms
Off 150 ms
Condition
Hard-Drive Activity LED
Hard-Drive Status LED
Green LED
Green LED
Amber LED