Dell PowerEdge C8000 User Manual

Page 169

Advertising
background image

Using the System Setup Program

169

PMC Configuration Information
The PMC configuration information is stored in the PMC board's internal

EEPROM. You must use TFTP server to retrieve the configuration data and

then use Notepad or a text editor to view or change the configuration data.
For example, a configuration data should have the following information:

By default, the PMC controller uses DHCP to acquire an IP address. The

system MUST follow the same DHCP retry mechanism that exists in the

BMCs (any parameter needed for this MUST be stored in the configuration

file). DHCP client MUST retry forever.

CONNECT.TYPE=STATIC/DHCP
IP=192.168.0.120
NETMASK=255.255.255.0
GATEWAY=192.168.0.1
TRAP.DESTINATION1=0.0.0.0
TRAP.DESTINATION2=0.0.0.0
TRAP.DESTINATION3=0.0.0.0
TRAP.DESTINATION4=0.0.0.0
TRAP.DESTINATION5=0.0.0.0
SNMP.RD.COMMUNITY.STR=public
SNMP.RW.COMMUNITY.STR=private
MANAGE.ACSOCKET.A.DEFAULT.POWER=ON/OFF
MANAGE.ACSOCKET.B.DEFAULT.POWER=ON/OFF
MANAGE.ACSOCKET.C.DEFAULT.POWER=ON/OFF
MANAGE.PDU.DEFAULT.POWER=ON/OFF
MANAGE.PSU.CONFIGURATION=5+1