Troubleshooting

263

To disable fresh air cooling in the enclosure:

1 Enter the following command:

ipmitool -I lanplus -P <password> -U <username> -H <BMC IP

address> raw <command>
where
-I lanplus is the LAN plus interface that uses the Remote Management

Control Protocol+ (RMCP+) protocol to communicate with the BMC

over an Ethernet LAN connection
-P <password> is the password for the given user ID
-U <username> is the username associated with the given user ID
-H <BMC IP address> is the BMC IP address
<command> is the command for configuring the fresh air mode
For example, the command line should have the following format:
ipmitool –I lanplus –P root -U root –H 192.168.70.58 raw 0x30 0x43 0x01

0x01

2 Enter the following command:

ipmitool –I lanplus –P root -U root –H 192.168.70.58 raw 0x30 0x43 0x01

0x0

To view the server enclosure fresh air status:

1 Enter the following command:

ipmitool -I lanplus -P <password> -U <username> -H <BMC IP

address> raw <command>
where
-I lanplus is the LAN plus interface that uses the Remote Management

Control Protocol+ (RMCP+) protocol to communicate with the BMC

over an Ethernet LAN connection
-P <password> is the password for the given user ID
-U <username> is the username associated with the given user ID