Using the System Setup Program

85

Chassis Level Capping

(Disabled default)

Set as chassis level or sled level power capping. (The

default setting is referred from BMC). The system

determines the power consumption of the enclosure and

sleds, and constantly attempts to maintain the enclosure’s

power consumption below the cap.

Sled Power Capping

(0 default)

NOTE:

This option is enabled when the Chassis Level

Capping is set to Disabled.
The sled’s own power capping infrastructure is able to

determine power consumption of the sleds. When set to 0,

the power capping function is disabled. The minimum

wattage rating should not less than 100 W and the

maximum wattage rating should not be more than the

power budget value. Settings range from 100 to 1000 W.