Using the System Setup Program

73

6 In the Remote Access Configuration screen, verify the following settings:

• Remote Access: Enabled
• Serial port number: COM2
• Serial Port Mode: 115200 8, n, 1
• Flow Control: None
• Redirection After BIOS POST: Always
• Terminal Type: ANSI
See "Remote Access Configuration" on page 113 for details. Make sure the

last four options syncs with the host and client.

7 In the Server screen, select BMC LAN Configuration and press <Enter>.
8 In the BMC LAN Configuration screen, verify the following settings:

• BMC LAN Port Configuration: Shared-NIC
• BMC NIC IP Source: DHCP or Static (Use DHCP if your network

servers are using automatic assignment of IP addresses)

• IP Address: 192.168.001.003
• Subnet Mask: 255.255.255.000
• Gateway Address: 000.000.000.000
See "Set BMC LAN Configuration" on page 111 for details. Make sure the

host and client are on the same network

9 Press <Esc> to return to the System Setup screen. Press <Esc> again,

and a message prompts you to save the changes.

Serial Port Connection List

Signal Type

Setup Option

OS
Setting

Output

Remote
Access

Serial Port
Number

Serial Port
Address

Serial Console

Redirection

Enabled

COM1

3F8h/2F8h

ttyS0

Serial Port

Enabled

COM1

2F8h/3F8h

ttyS1

BMC Serial

Over LAN

Enabled

COM2 as SOL 3F8h/2F8h

ttyS1

Management

Port

Enabled

COM2 as SOL 2F8h/3F8h

ttyS0