1 oam control, 1 oam operational status – CANOGA PERKINS 9145EMP NID Software Version 4.0 User Manual

Page 113

Advertising
background image

9145EMP NID Software User’s Manual

Link OAM

OAM Control

98

9.1 OAM Control

From the Link OAM screen, select OAM Control (1) and press Enter. The OAM Control (Figure
9-2)
opens.

The OAM Control screen has two sections. The top of the screen shows status information. The
bottom of the screen allows you to control the OAM settings and displays configuration
parameters. Each screen contains Link OAM status and configuration for two ports. To navigate
to different ports, use the (N)ext and (P)revious commands. Press Esc to return to the Link OAM
menu.

The standard configuration parameters and their corresponding MIB objects are listed in the
section “User Interface MIB Objects”.

Figure 9-2 OAM Control screen

9.1.1 OAM Operational Status

At initialization and failure conditions, two OAM entities on the same full-duplex Ethernet link
begin a discovery phase to determine what OAM capabilities may be used on that link. The
following is the list of possible values:

Disabled Returned if OAM is disabled on this interface via the OAM Admin State.

Canoga Perkins Corp. Ethernet Network Interface Device 21-MAR-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59
--------------------------------------OAM CONTROL------------------------------
Usr1 Port Usr2 Port
--------- ---------
OAM Operational Status Disabled Disabled
OAM Max PDU Size 1518 1518
OAM Revision 1 1
OAM Functions Supported Loopback Loopback
Link Events Link Events

OAM Loopback Status No Loopback No Loopback
OAM Remote Link Fault No No

1) OAM Admin State Disabled Disabled
2) OAM Mode Active Active
3) OAM Loopback Command No Loopback No Loopback
4) Process Rx Loopback OAMPDU No No
5) Fwd Critical Event No No
Select [(N)ext, (P)rev, or [1-6]]:
------------------------------------Messages-----------------------------------