6 maintenance end points – CANOGA PERKINS 9145EMP NID Software Version 4.0 User Manual

Page 166

Advertising
background image

Service OAM

9145EMP NID Software User’s Manual

Maintenance End Points

151

10. Press Esc to return to the Maintenance Entity Group List screen.

Figure 11-17 Maintenance Entity Group Attributes screen

11.6 Maintenance End Points

A Maintenance Association End Point (MEP) is an actively managed CFM entity that can
generate and receive CFM PDUs and track any responses. Up to 256 MEPs can be configured in
a 9145EMP NID device. For more information, see the section “Logical Positioning of MEPs and
MIPs” on page 128.

Canoga Perkins Corp. Ethernet Network Interface Device 21-MAR-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59
---------------------MAINTENANCE ENTITY GROUP ATTRIBUTES------------------------

MEG ID:100 Name: test-meg
Name Format: ICC-based Format
Level: 2
1) CCM Interval: 1 sec

VLAN Tag Type: C-Tag
VLAN Multiplexing record. 100

VLAN List: N/A

2) Add VLAN to VLAN List.
3) Remove VLAN from VLAN List.

4) View/Modify Peer MEPs list.
5) Permissions (Sender ID): None

Select [1-6] for attributes:

------------------------------------Messages-----------------------------------