8 loopback procedures, 1 initiating a loopback request, Figure 11-28) – CANOGA PERKINS 9145EMP NID Software Version 4.0 User Manual

Page 178

Advertising
background image

Service OAM

9145EMP NID Software User’s Manual

Maintenance End Points

163

Figure 11-28 SOAM Linktrace Report screen

11.6.8 Loopback Procedures

A loopback request is initiated by a MEP to verify the connectivity to a specified target MEP or
MIP in the network.

NOTE: Only one Loopback session can be active at a time for the entire system.

11.6.8.1 Initiating a Loopback Request

1. On the Maintenance End Point Attributes screen (Figure 11-21 for 802.1ag or Figure 11-

22 for Y.1731), type L and press Enter.

If a Loopback request was already initiated from the MEP, a Loopback Monitoring
screen (Figure 11-29 for unicast, Figure 11-30 for sweep, or Figure 11-31 for mul-
ticast) opens.

Otherwise, the Loopback Request screen (Figure 11-32) opens.

2. To change the loopback mode, on the Loopback Request screen, type 1 and press Enter.

For 802.1ag, select unicast regular or unicast sweep.

For Y.1731, select unicast regular, unicast sweep, or multicast.

Sweep loopback allows you to initiate a procedure for which the size of a loopback
message is automatically incremented by 1 Byte within a preset limit.

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59
------------------------------SOAM LINKTRACE REPORT ----------------------------

Source MEP ID: 1
Destination: Mep ID: 2
MAC: 00:40:2A:01:ED:E3
Destination reached: Yes
Number of hops to destination: 1
Number of replies: 1

Reply number: 1
TTL: 62
Responder MAC address: 00:40:2A:01:ED:E3
LTM was forwarded: No
Terminal MEP was reached: Undefined
Relay action: Undefined
Egress action: Ok
Egress address: 00:40:2A:01:ED:E3

Select [(F)irst, (P)rev, (N)ext, (L)ast] to change pages,
R)efresh, ESC to return:
------------------------------------Messages-----------------------------------

Advertising