9145EMP NID Software User’s Manual

Service OAM

Maintenance Intermediate Points

168

11.7.2 Create a Maintenance Intermediate Point

1. On the Maintenance Intermediate Point List screen (Figure 11-33), type A and press

Enter. You are prompted to enter A for 802.1ag or Y for Y.1731.

2. Type A or Y and press Enter. The Create a New Maintenance Intermediate Point screen

(Figure 11-34 for 802.1ag or Figure 11-35 for Y.1731) opens. The MD/MEG ID field is
highlighted.

3. Type an MD ID (for 802.1ag) or MEG ID (for Y.1731) and press Enter. (To view a list of

MD/MEGs, press CTRL-L, type S to select, and press Enter). The MIP ID field is
highlighted.

4. Type a MIP ID and press Enter. The Admin Status field is highlighted.

5. In the Admin status field, select Enabled or Disabled and press Enter.

6. To accept the new Maintenance Intermediate Point settings, type A and press Enter. The

Maintenance Intermediate Point Attributes screen (Figure 11-36 for 802.1ag or Figure 11-
37
for Y.1731) opens.

7. To modify an attribute value, type the number of the attribute and press Enter, or press

Esc to return to return to the Maintenance Intermediate Point List screen.

Figure 11-34 Create a New Maintenance Intermediate Point screen (802.1ag)


Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59

-----------------CREATE A NEW MAINTENANCE INTERMEDIATE POINT--------------------

1) MD ID 0
2) MIP ID: 0
3) Admin status: Disabled

Select [1-3] for attributes:
------------------------------------Messages-----------------------------------