4 oam event configuration – CANOGA PERKINS 9145EMP NID Software Version 4.0 User Manual

Page 118

Advertising
background image

Link OAM

9145EMP NID Software User’s Manual

OAM Event Configuration

103

9.4 OAM Event Configuration

To configure errors in the OAM, from the Link OAM screen, type 4 and press Enter. The OAM
Event Configuration screen (Figure 9-5) opens. Press Esc to return to the Link OAM menu.

Figure 9-5 Event Configuration screen

Canoga Perkins Corp. Ethernet Network Interface Device 21-MAR-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59
--------------------------------OAM EVENT CONFIGURATION------------------------
User1 Port User2 Port
--------- ------------
1) Errored Symbol Period Window 125000000 125000000
2) Errored Symbol Period Threshold 1 1
3) Errored Frame Window (secs) 1.0 1.0
4) Errored Frame Threshold 1 1
5) Errored Frame Period Window 148809 148809
6) Errored Frame Period Threshold 1 1
7) Errored Frame Seconds Window (secs) 60.0 60.0
8) Errored Frame Seconds Threshold 1 1
9) Transmit Event Notification Count 1 1
10) Event Log Frequency (in 100 ms) 600 600
11) Send Errored Symbol Period Events Enabled Enabled
12) Send Errored Frame Events Enabled Enabled
13) Send Errored Frame Period Events Enabled Enabled
14) Send Errored Frame Seconds Events Enabled Enabled
15) Send Dying Gasp Events Enabled Enabled
16) Send Critical Events Enabled Enabled

Select [[1-16], (F)irst, (N)ext, (P)rev, (L)ast]
------------------------------------Messages-----------------------------------

Advertising