11.6.5 Interoperability between a Y.1731 MEP and 802.1ag MEPs

In general, an 802.1ag MEP cannot interoperate correctly with a Y.1731 MEP; that is, they cannot
correctly exchange CCM messages. Their respective standards do not provide compatibility
methods.

The Canoga Perkins 9145EMP NID does, however, provide a configuration method that will
allow interoperability between a Y.1731 MEP and an 802.1ag MEP operating in the same
administrative domain at the same level.

Figure 11-23 Create a New Maintenance Entity Group screen

To configure the operation of the MEPs in compatible mode, use the following steps:

1. For the 802.1ag MEP, configure the corresponding MD Domain Name as empty. Only the

MA name will be transmitted in the CCM packet.

2. For the Y.1731 MEP, configure the corresponding MEG name in Character string mode.

The MEG name configured for the Y.1731 MEP must match the name defined for the MA
of the 802.1ag MEP.

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59
--------------------CREATE A NEW MAINTENANCE ENTITY GROUP-----------------------

1) MEG ID: 2
2) Level: 1
3) Name:
4) Name Format: ICC-based Format
5) VLAN Tag Type: T-Tag

6) EVC Configuration Record: 1

7) CCM Interval: 1 sec
8) Permissions (Sender ID): None

Select [1-8], (A) to accept: