Configuring EVC
EVC Configuration
198
12.2.5 S-TPID/T-TPID Configuration
S-TPID and T-TPID are configured at the system level. The allowed values are 88A8 and 8100.
1. On the EVC Configuration screen, type 2 and press Enter. The S-TPID/T-TPID
Configuration screen (Figure 12-16) opens.
2. To edit the S-Tag TPID, type 1 and press Enter. Use the Space bar to select 88A8 or
8100, and press Enter.
3. To edit the T-Tag TPID, type 2 and press Enter. Use the Space bar to select 88A8 or
8100, and press Enter.
4. Type A to accept your changes.
5. Press Enter to return to the S-TPID/T-TPID Configuration screen.
6. Press Esc to return to the EVC Configuration screen.
Figure 12-16 S-TPID/T-TPID Configuration screen
Canoga Perkins Corp. Ethernet Network Interface Device 21-MAR-2011
9145EMP-761-4-0 V40.43 03:29:52
-------------------------S-TPID/T-TPID CONFIGURATION---------------------------
1) S-Tag TPID: 88A8
2) T-Tag TPID: 8100
Select [1-2]:
------------------------------------Messages-----------------------------------