PROFIBUS communication function of DL-PD1

This section describes the overview of the PROFIBUS DP communication functions the
DL-PD1 supports.

Overview

The DL-PD1 operates as a slave unit for PROFIBUS DP. The sensor amplifier output or
comparator value can be read via the cyclic communication, and the sensor amplifier's
external input ON/OFF can be controlled. Also, setting the DL-PD1 or sensor amplifier
connected to DL-PD1 and reading/writing the status of them are possible via the acyclic
communication of the DP-V1 service.

"Overview of PROFIBUS DP Communication" (page 3-17)
"DP-V1 Service" (page 3-26)

IN area

OUT area

Output

Judgment value

Error information

External Input

PROFIBUS DP

master

DL-PD1

Sensor amplifier

Output

Judgment value

Error information

Setting value

Exteral input

Output

Judgment value

Error information

Setting value

External Input

Cyclic
communication

Cyclic
communication

DP-V1 service

Output

Judgment value

Error information

Setting value

Exteral input

IN area

OUT area

Read/write parameters