KEYENCE DL-PD1 User Manual

Page 58

Advertising
background image

3-6

DP-V1 Service

3-34

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -

Ex
ec

ut

in

g C
om
m

uni

ca

tion

3

*1 The error content of the sensor amplifier can be checked by noting the ON/OFF

state of each bit.
OFF (0): No error; ON (1): Error
More than one error may occur simultaneously. For details of each error, refer to the
GT2 Series User's Manual.

*2 Details of output status can be checked by noting the ON/OFF state of each bit.
*3 If the judgment value is correct, the parameter range is -199.9999 to +199.9999.

When the comparator value is over range, "+999.9999" is stored.
When the comparator value is under range, "-999.9999" is stored.
When the comparator value is invalid, "-999.9998" is stored.
When an error occurs, "+1000.0000" is stored.

*4 When you use the calculation function and calculation setting is set to other than

standard difference display, a reading error occurs on the expansion unit.

*5 In the calculation-only mode, a reading error occurs on the main unit.
*6 This parameter can be used only when the detection mode of the sensor amplifier is peak-to-

peak hold. A reading error occurs when the mode is set to other than peak-to-peak hold.
This parameter may be used for judging the outer diameter of cylinders, in order to
read the peak and bottom values during measurement.

*7 When you do not use the calculation function, a reading error occurs.

When the calculation setting is set to other than standard difference display, a
reading error occurs on the expansion unit.
When the calculation setting is set to difference display, a reading error occurs on the main unit.

*8 These parameters cannot be read/written when a sensor amplifier of GT2-71MC*

series is used.

*9 This parameter cannot be written to expansion units if the key lock function is used by the

main unit when simultaneous input is active. When a sensor amplifier of GT2-100* series
is used, this parameter cannot be written to units other than the main unit (ID: 01).

*10 This parameter cannot be written when the key lock function is used.

201

Product name 2

*17

DINT/

STRING

R

GT2-7* main unit:="71*/"
GT2-7* expansion unit:="72*/"
GT2-71MC:="71MC"
GT2-100*:="100*"

202

Product name 3

*17

DINT/

STRING

R

GT2-7* main unit:="75* "
GT2-7* expansion unit:="76* "
GT2-71MC:="* "
GT2-100*:=""

203

Product name 4

*17

DINT/

STRING

R

GT2-7* main unit:=""
GT2-7* expansion unit:=""
GT2-71MC:=""
GT2-100*:=""

204 to

217

Reserved for system

218

Unit

219 to

223

Reserved for system

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value