KEYENCE DL-PD1 User Manual
Page 53

3-6
DP-V1 Service
3-29
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -
Execu
ting Communi
cat
ion
3
*1 Functions assigned to the external input request 1 to 4 are as follows:
•
External input request 1: PRESET input
•
External input request 2: TIMING input
•
External input request 3: RESET input
•
External input request 4: ERROR CLEAR input
Refer to the GT2 series user's manual.
*2 If the judgment value is correct, the parameter range is -199.9999 to +199.9999.
•
When the comparator value is over range, "+999.9999" is stored.
•
When the comparator value is under range, "-999.9999" is stored.
•
When the comparator value is invalid, "-999.9998" is stored.
•
When an error occurs, "+1000.0000" is stored.
*3 When you use the calculation function and calculation setting is set to other than
standard difference display, a reading error occurs on the expansion unit.