3-2

Hardware configuration

3-7

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -

Execu

ting Communi

cat
ion

3

Input/Output size

When DL-PD1 is in the monitor mode

The input/output size changes according to the number of sensor amplifiers connected.
Assign the "DL-PD1" and each sensor amplifier to the PROFIBUS DP system on the
hardware configuration using the configuration software of PROFIBUS DP.

*

How many sensor amplifiers can be connected depends on the sensor amplifiers to
be connected. For specific numbers of connections, refer to the manual of each
sensor amplifier.

When DL-PD1 is in the I/O mode

The input/output size is fixed regardless of the number of sensor amplifiers connected.
Assign the "DL-PD1 without sensor amplifier" to the PROFIBUS DP system on the
hardware configuration using the configuration software of PROFIBUS DP.

Slot

Cyclic communication

input

output

0

2 bytes

1 byte

1

:

15*

7 bytes

1 byte

Slot

Cyclic communication

input

output

0

10bytes

10bytes