3 parameterization, Parameterization -8, Parameterization – KEYENCE DL-PD1 User Manual

Page 32: Standard parameter, Execu ting communi cat ion, Parameters specified by profibus dp/dpv1 standard

Advertising
background image

3-8

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -

Execu

ting Communi

cat
ion

3

3-3

Parameterization

Set parameters on the configuration software of PROFIBUS DP.
Set as necessary.

Standard parameter

Parameters specified by PROFIBUS DP/DPV1 standard

Octet

Name

Description

Value

1

Station Status

Station status

BIT2-0: reserved
BIT3: Watchdog on
BIT4: Freeze mode request
BIT5: Sync mode request
BIT6: Unlock request
BIT7: Lock request

2

WD_Fact_1

Watchdog element 1

-

3

WD_Fact_2

Watchdog element 2

-

4

TSDR

Shortest TSDR time

-

5

Ident number (H)

Manufacturer code (high byte)

0D

H

6

Ident number (L)

Manufacturer code (low byte)

FD

H

7

Group ID

Group assignment for broadcast and
multi cast (SYNC,FREEZE, CLEAR)

-

8

DPV1 Status1

DPV1 status 1 (See EN50170.)

BIT1-0: reserved
BIT2: Watchdog time base 1 ms
BIT4-3: reserved
BIT5: 0 (fixed)
BIT6: Fail_safe
BIT7: DP-V1_Enable

(Default value: 1100 0000

B

)

9

DPV1 Status2

DPV1 status 2 (See EN50170.)

BIT0: Check_Cfg_Mode
BIT1: reserved
BIT7-2: 0 (fixed)

(Default value: 0000 0001

B

)

10

DPV1 Status3

DPV1 status 3 (See EN50170.)

0 (fixed)

Advertising