6 dp-v1 service, Ex ec ut in g c om m uni ca tion – KEYENCE DL-PD1 User Manual

Page 57

Advertising
background image

3-6

DP-V1 Service

3-33

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -

Ex
ec

ut

in

g C
om
m

uni

ca

tion

3

154

Batch setting (GT2-100* only)

*14

DINT

R/W

0

0: Individual
1: Batch

155

Analog Range setting

*15

DINT

R/W

0

0: Default
1: Free range setting

156

Free range setting (Hi)

*15

DINT

R/W

+012.0000 -199.9999 to +199.9999

157

Free range setting (Lo)

*15

DINT

R/W

000.0000

-199.9999 to +199.9999

158 to

159

Reserved for system

160

Group5 Entry count

DINT

R

15

161

R.V. (base of calc.) ID01

*3

*16

DINT

R

162

R.V. (base of calc.) ID02

*3

*16

DINT

R

163

R.V. (base of calc.) ID03

*3

*16

DINT

R

164

R.V. (base of calc.) ID04

*3

*16

DINT

R

165

R.V. (base of calc.) ID05

*3

*16

DINT

R

166

R.V. (base of calc.) ID06

*3

*16

DINT

R

167

R.V. (base of calc.) ID07

*3

*16

DINT

R

168

R.V. (base of calc.) ID08

*3

*16

DINT

R

169

R.V. (base of calc.) ID09

*3

*16

DINT

R

170

R.V. (base of calc.) ID10

*3

*16

DINT

R

171

R.V. (base of calc.) ID11

*3

*16

DINT

R

172

R.V. (base of calc.) ID12

*3

*16

DINT

R

173

R.V. (base of calc.) ID13

*3

*16

DINT

R

174

R.V. (base of calc.) ID14

*3

*16

DINT

R

175

R.V. (base of calc.) ID15

*3

*16

DINT

R

176 to

191

Reserved for system

192

Group6 Entry count

DINT

R

11

193

Product code

DINT

R

GT2-7* main unit:=4006
GT2-7* expansion unit:=4007
GT2-71MC:=4008
GT2-100* main unit:=4010
GT2-100* expansion unit:=4011

194 to

199

Reserved for system

200

Product name 1

*17

DINT/

STRING

R

GT2-7* main unit:="GT2-"
GT2-7* expansion unit:="GT2-"
GT2-71MC:="GT2-"
GT2-100*:="GT2-"

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value

Advertising