3-5

Overview of PROFIBUS DP Communication

3-20

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -

Execu

ting Communi

cat
ion

3

Sensor amplifier (Slot 1 to 15)

Input

*

"a" represents a Slot number. For example, the Octet value to Slot 1 is 2, 3, 4, or 5 to
8.

Octet

Bit

Function name

Description

Value

2+7(a-1)*

0

High

ON/OFF of the High state of the
sensor amplifiers is output.

0: OFF
1: ON

1

Low

ON/OFF of the Low state of the
sensor amplifiers is output.

0: OFF
1: ON

2

Go

ON/OFF of the Go state of the
sensor amplifiers is output.

0: OFF
1: ON

3

HH

ON/OFF of the HH state of the
sensor amplifiers is output.

0: OFF
1: ON

4

LL

ON/OFF of the LL state of the
sensor amplifiers is output.

0: OFF
1: ON

5

Reserved for system

-

-

6

Reserved for system

-

-

7

Reserved for system

-

-

3+7(a-1)*

0

Reserved for system

-

-

1

Comparator value invalid

Stores the comparator value status.

0: Normal
1: Comparator value invalid
“----”

2

Comparator value under range Stores the comparator value status.

0: Normal
1: Comparator value under
range “-FFFF”

3

Comparator value over range

Stores the comparator value status.

0: Normal
1: Comparator value over
range “FFFF”

4

Reserved for system

-

-

5

Reserved for system

-

-

6

Reserved for system

-

-

7

Error status

Stores the error status of the sensor
amplifiers.

"

Types of error and error code"

(page 4-3)

0: No error occurred.
1: Error occurred.

4+7(a-1)*

0

External input response 1

Stores the external input response
to the sensor amplifier.

0: No input
1: Input reception

1

External input response 2

Stores the external input response
to the sensor amplifier.

0: No input
1: Input reception

2

External input response 3

Stores the external input response
to the sensor amplifier.

0: No input
1: Input reception

3

External input response 4

Stores the external input response
to the sensor amplifier.

0: No input
1: Input reception

4

Reserved for system

-

-

5

Reserved for system

-

-

6

Reserved for system

-

-

7

Reserved for system

-

-

5+7(a-1)* to

8+7(a-1)*

0 to 7 Comparator value box

Used when reading the comparator
value (P.V. value).

INT32(LITTLE)

Advertising