107

E SR-750 UM

Reference program chart

Description of the reference program

Rung1 : When Read Complete and Read Failure are OFF, the read start

message is sent at the rising of B9:0:0.

Rung2 : For each timeout of the timer, Get Attribute Single is performed for Read

Status.
The result is written to Read Status Res.

Rung3 : At the rising of either Result Status Res[1].0(Read Complete) or 1(Read

Failure), Get Result Data is performed.
The result is written to Read Data Res.

Rung4 : Read Complete Clear is performed.
Rung5 : This starts B9:0/1 and sends the read end message.
Rung6 : The timer is being performed to perform Rung2.

( EN )

( DN )

( ER )

ONS

MSG

/

/

B9:0/0

N25:1/0 N25:1/1

Communication Command

CIP Generic

Size in byte(Receive)

0

Data Table Address(Receive)

-

Size in byte(Send)

2

Data Table Address(Send)

N11

Service

Custom

Service Code

4b(Hex)

Class 69(Hex)
Instance

1

Attribute

0

( EN )

( DN )

( ER )

ONS

MSG(MG22)

T10:1/DN

Communication Command

CIP Generic

Size in byte(Receive)

8

Data Table Address(Receive)

N25

Size in byte(Send)

0

Data Table Address(Send)

-

Service Get

Attribute

Single Service

Code

E(Hex)
Class 69(Hex)
Instance 1
Attribute 64

( EN )

( DN )

( ER )

ONS

MSG(MG23)

N25:1/0

N25:1/1

Communication Command

CIP Generic

Size in byte(Receive)

100

Data Table Address(Receive)

N27

Size in byte(Send)

4

Data Table Address(Send)

N26

Service

Custom

Service Code

55(Hex)

Class 69(Hex)
Instance 1
Attribute 0

( U )

Timer

Rung1

Rung2

Rung3

( EN )

( DN )

( ER )

ONS

MSG(MG20)

MG23:0/DN

Communication Command

CIP Generic

Size in byte(Receive)

0

Data Table Address(Receive)

-

Size in byte(Send)

0

Data Table Address(Send)

-

Service

Custom

Service Code

5A(Hex)

Class

69(Hex)

Instance

1

Attribute

0

Rung4

( EN )

( DN )

( ER )

ONS

B9:0/1

Communication Command

CIP Generic

Size in byte(Receive)

0

Data Table Address(Receive)

-

Size in byte(Send)

0

Data Table Address(Send)

-

Service Custom
Service Code

4C(Hex)

Class 69(Hex)
Instance 1
Attribute 0

( DN )

TON

Timer T10:1
Time Base

0.01

Preset 100

Rung5

Rung6

MSG (MG24)

[Message communication] Buffer Overflow Error and
General Error occurred.

This is a reference program to disable Buffer Overflow Error and General Error
using the message communication.

„

For the KV Series

Reference program chart

„

For the Control Logix/Compact Logix (RSLogix 5000)

Reference program chart

„

For the Micro Logix (RSLogix 500)

Reference program chart

Point

With this operation, the Error Clear operation is performed for the
SR-750.
Buffer Overflow Error and General Error are cleared, and the result
data within Result Data Available, Result Data Strobe and SR-750
are cleared.
When performing using the cyclic communication, the operation
will become the same by setting the Error Clear bit to ON.

↑

↑

REQ

R30700

REQ

R30700

Message communication

start request

R31700

Message communication

complete

R30700

Message communication

start request

#0

U_MSGTO

' Data are stored using the box script.

' Data can also be stored with the MOV command.

DM0 = 192 ' IP address the first byte (arbitrary)

DM1 = 168 ' IP address the second byte (arbitrary)

DM2 = 100 ' IP address the third byte (arbitrary)

DM3 = 100 ' IP address the fourth byte (arbitrary)

DM4 = 83 ' service cord (0x53)

DM5 = 105 ' class ID

(0x69)

DM6 = 1 ' instance ID

(0x01)

DM7 = 0 ' attribute ID

(0x00)

DM100 = 0 ' Sent data in message communication

KV-5500

#0

U_MSGTO

KV-5500

DM100

DM0

Unit No.

Message

communication

Unit No.

Message

communication

( EN )

( DN )

( ER )

ONS

Service Type

Custom

Service Code

53(Hex)

Class

69(Hex)

Instance

1

Attribute 0
Source Element

-

Source Length

-

Destination

-

MSG

( EN )

( DN )

( ER )

ONS

MSG

Communication Command

CIP Generic

Size in byte(Receive)

0

Data Table Address(Receive) -
Size in byte(Send)

0

Data Table Address(Send)

-

Service Custom
Service Code

53(Hex)

Class 69(Hex)
Instance 1
Attribute 0

Advertising