KEYENCE SR-750 Series User Manual

Page 22

Advertising
background image

22

E SR-750 UM

Modulation

MOD (Modulation)

Description

Evaluates the variation degree in cell
brightness

Calculation
formula

Each cell's MOD = 2 ½ (abs (R-GT)/SC)

R

: Brightness value

GT : Binarization threshold value
SC : Symbol contrast

Criterion

Reflectance margin

RM (Reflectance Margin)

Description

Evaluates the variation degree in cell
brightness with black and white of the correct
cell considered.

Calculation
formula

[White cell]
R >= GT

→ MARGIN = 2 ½ (R-GT)/SC

R < GT

→ MARGIN = 0

[Black cell]
R < GT

→ MARGIN = 2 ½ (GT-R)/SC

R >=

→ MARGIN = 0

MARGIN : Margin of each cell
R

: Brightness value

GT

: Binarization threshold value

SC

: Symbol contrast

Criterion

Fixed pattern damage

FPD (Fixed Pattern Damage)

Description

Evaluates the degree of the fixed pattern
damage (area on the right) dependent on the
code type.

Calculation
formula

Criterion

Format information damage

FID

(Format Information Damage)

Description

Evaluates the format information damage
degree of QR code.

Calculation
formula

Criterion

Version information damage

VID

(Version Information Damage)

Description

Evaluates the version information damage
degree of QR code (Model 2, version 2 and
later versions).

Calculation
formula

Criterion

Axial nonuniformity

AN (Axial Nonuniformity)

Description

Evaluates the distortion degree in vertical and
horizontal size of the code.

Calculation
formula

AN = abs (Xavg = Yavg)/((Xavg = Yavg)/2)

Xavg : Average cell size in horizontal

direction

Yavg : Vertical cell size in horizontal

direction

Criterion

A : less than 0.06
B : 0.06 to 0.08
C : 0.08 to 0.10
D : 0.10 to 0.12
F : more than 0.12

Grid nonuniformity

GN (Grid Nonuniformity)

Description

Evaluates the maximum position slip of each
cell

Calculation
formula

GN = Hmax/X

Hmax : Maximum position slip amount
X

: Cell size

Criterion

A : less than 0.38
B : 0.38 to 0.50
C : 0.50 to 0.63
D : 0.63 to 0.75
F : more than 0.75

Unused error correction

UEC

(Unused Error Correction)

Description

Evaluates the ratio of error correction unused
at the time of decoding.

Calculation
formula

UEC = 1.0 - ((e + 2t)/(d - p))

e : Number of code words that cannot be

read

t : Number of error code words
d : Number of error corrected code words
p : Number of error detected code words

Criterion

A : more than 0.62
B : 0.50 to 0.62
C : 0.37 to 0.50
D : 0.25 to 0.37
F : less than 0.25

Print growth (horizontal)

PGH

(Print Growth Horizontal)

Description

Evaluates the mark cell growth in the
horizontal direction.

Calculation
formula

(D - 0.5)/0.15

D : On the horizontal clock pattern

Ratio of the number of pixels of mark
cell

Criterion

A : -0.50 to 0.50
B : -0.70 to -0.50 or 0.50 to 0.70
C : -0.85 to -0.70 or 0.70 to 0.85
D : -1.00 to -0.85 or 0.85 to 1.00
F : less than -1.00 or more than 1.00

Print growth (vertical)

PGV (Print Growth Vertical)

Description

Evaluates the mark cell growth in the vertical
direction.

Calculation
formula

(D - 0.5)/0.15

D : On the vertical clock pattern

Ratio of the number of pixels of mark
cell

Criterion

A : -0.50 to 0.50
B : -0.70 to -0.50 or 0.50 to 0.70
C : -0.85 to -0.70 or 0.70 to 0.85
D : -1.00 to -0.85 or 0.85 to 1.00
F : less than -1.00 or more than 1.00

Advertising