Misc – KEYENCE SR-750 Series User Manual

Page 48

Advertising
background image

48

E SR-750 UM

• Keep connected

Check this option to let reader send connection requests whenever the
connection is closed.
Default

: Disabled

Setting range : Disable or Enable

• Send NOOP command

Sets whether to send NOOP commands periodically.
Default

: Enable

Setting range : Disable or Enable

• NOOP command interval (minutes)

Sets the sending interval for NOOP commands.
Default

: 1 minute

Setting range : 1 to 10 (minutes)

Misc

• Output data on TEST button

Sets the data output when the TEST button is pressed.
Default

: Enable

Setting range : Disable or Enable

• Filling size

Sets the data filling size. This fills the missing digits with the specified data filling
characters when the read data is less than the set size.
Default

: 0

Setting range : 0 to 999

• Filling character

Sets the data filling characters.
Default

: 20 (hexadecimal display, ASCII characters "(SP)")

Setting range : Enter any single ASCII or hexadecimal characters.

• Silent Mode

Set this option to enable silent mode.
Default

: Not selected

Setting range : Comparison OK and Read OK, Comparison NG, Read ERROR,

Stable Reading (OK/Comparison NG), Unstable Reading (OK/
Comparison NG), Preset Result, or Test mode

• Reader

Sets the reader name.
Default

: READER

Setting range : Up to 8 characters

• Monitor output data priority display position

Sets the monitor output data priority display position.
Default

: Forward

Setting range : Forward or Backward

• TUNE button

Sets Enable/Disable of the TUNE button.
Default

: Unlock

Setting range : Unlock or Lock

• Laser-aim option with TUNE button

Sets the pointer lighting condition by TUNE button operation.
Default

: By operation

Setting range : Lock .............................The laser pointer does not light up by

TUNE button operation or each operation
mode.

Test mode only ............Only in the test mode, the pointer lights

up by the TUNE button.

Run mode only ............Only in the run mode, the pointer lights

up by the TUNE button.

By operation ................Regardless of the test mode or the run

mode, the pointer lights up by the TUNE
button.

• Display bank number

Sets the parameter bank number display of reading success for the multiple LED
indicator.
Default

: Enable

Setting range : Enable or Disable

„

Trigger command response

• Specify response character

Sets the LON and LOFF trigger command response.
Default

: Disable

Setting range : Disable, SR-600 compatible and User setting

• SR-600 compatible

Set this option to enable the SR-600 compatible mode. For details, refer to

"3-9 SR-600 Compatible Output Mode (Page 19)".

• User setting

Sets the response for the following commands to Success response character
or Failure response character.

• LON
• LONmm
• LOFF
• PRON
• PROFF
• RESET
• BCLR

• Success response character

Sets the response character string when LON and LOFF is normally processed.
Default

: OK (0x4F4B)

Setting range : Up to 8 characters

Set with ASCII or HEX.

• Failure response character

Sets the response character string when the process (e.g. LON is sent during
LON. LOFF is sent during reading standby.) fails.
Default

: ER (0x4552)

Setting range : Up to 8 characters

Set with ASCII or HEX.

„

SNTP

• SNTP server address

Sets the SNTP server address.

• Time zone

Sets the time zone of the country where SR-750 is used.
Default

: +9:00 Japan, Seoul

• Update cycle (min)

Sets the time update cycle.
Default

: 1

Setting range : 1 to 99