1 ethernet/ip, Ethernet/ip, List of applicable plc models – KEYENCE SR-750 Series User Manual

Page 94: Cyclic communication and message communication, Scanner and adaptor, Cyclic communication, Message communication, Sr-750 series ethernet/ip function overview

Advertising
background image

94

E SR-750 UM

11-1

EtherNet/IP

This section describes an overview of EtherNet/IP.

EtherNet/IP

EtherNet/IP is an industrial communications network proposed by ODVA (Open
DeviceNet Vendor Association, Inc.).
EtherNet/IP communication can share the network with normal Ethernet
communication.

„

Scanner and adaptor

In EtherNet/IP communication, one device opens a communication line called
"connection" to another device.
The device which opens the connection is called the "scanner" (originator), and the
receiving device is called the "adaptor" (target). A PLC is primarily used as the
scanner. The SR-750 becomes the adaptor device.

Cyclic communication and message communication

In EtherNet/IP, there is cyclic communication (Implicit message) that handles
periodic sending and receiving of data, and there is also message communication
(Explicit message) which handles sending and receiving of commands/responses
arbitrarily.

„

Cyclic communication

In cyclic communication, RPI (communication cycle) can be set according to the
priority of data that is sent and received. Overall communication load adjusted data
can be sent and received.

„

Message communication

In message communication, timing is controlled through commands/responses.

SR-750 Series EtherNet/IP Communication Specifications and Function Overview

„

SR-750 Series EtherNet/IP Communication Specifications

* There is a total of 16 connections in cyclic communication and message

communication.

Cyclic
communication
(Implicit message)

Number of
connections

16

*

Communication
size

KEYENCE KV Series

4 to 1444 bytes

Rockwell Automation
ControlLogix
CompactLogix

4 to 496 bytes

OMRON CJ/CS Series

4 to 1436 bytes

Message
communication
(Explicit Message)

Number of
connections

16

*

Applicable
messaging
methods

UCMM (unconnected type), Class 3 (connected
type)

Communication cycle (RPI) setting
SR-750 (1): 10 ms
SR-750 (2): 50 ms
SR-750 (3): 1000 ms

SR-750 (1)

RPI = 10 ms

SR-750 (2)

RPI = 50 ms

SR-750 (3)

RPI = 1000 ms

EtherNet/IP

PLC

The communication cycle (RPI) put together in order of priority can be set and network load can be adjusted.

Send

Receive

PLC

Receive

Process, operation

Send

SR-750

Command

Response

Data

Scanner

adaptor

„

SR-750 Series EtherNet/IP function overview

The following describes the functions that can control the SR-750 Series using
EtherNet/IP.

List of applicable PLC models

Refer to each PLC instruction manual for the corresponding PLC setting
procedures.

PLC manufactured by KEYENCE

PLC manufactured by Rockwell Automation

PLC manufactured by Omron

Function

Description

Reading instruction

Performs reading instructions.
Also performs reading end, bank setting reading, etc.

Preset instructions

Records successfully read data as preset data.
Also registers or deletes preset data from the PLC.

Calibration
instructions

Performs calibration. Can save calibration results in the set bank.

Error-handling

Checks the cause of the error that occurred in the main unit, and
returns the error.
(Example: Buffer overflow check/cancellation)

Main unit status
acquisition

Checks the main unit status (BUSY status).

Operation results
acquisition

Acquires read data.
When set to silent mode, the read data is not updated.

Terminal status
acquisition

Acquires input terminal and output terminal status.

Main unit reset
instructions

Displays the SR-750 Series software reset.

NOTICE

About the exclusion process

The SR-750 Series can simultaneously give control instructions to
multiple interfaces (I/O terminal, RS-232C, Ethernet Communication
(TCP/IP), EtherNet/IP communication, test key operation). However,
when a control instruction is being received from one interface,
instructions from other interfaces cannot be received.

KV Series

PLC model

EtherNet/IP

Communication unit

Firmware

version

Software used

Version of

software used

KV-3000

KV-EP21V

Ver. 2 or later

KV STUDIO

Ver. 6.0 or later

KV-5000

KV-EP21V

Ver. 2 or later

KV-5500

-(KV-5500 built-in
port or KV-EP21V)

Ver. 2 or later

ControlLogix category PLC

PLC model

EtherNet/IP

Communication unit

Firmware

version

Software used

Version of

software used

1756 ControlLogix 1756-ENBT/1756-

EN2T

Ver. 13 or later

RsLogix5000

Ver. 13 or later

1769
ConpactLogix

-(SR-750 built-in
port)

Ver. 13 or later

SLC5/05 category PLC

PLC model

EtherNet/IP

Communication unit

Firmware

version

Software used

Version of

software used

1747 SLC5/05

-(SR-750 built-in
port)

OD firmware
level Series C,
FRN 10 or later

RsLogix500

Ver. 7.10 or later

1761/1766
MicroLogix

-(SR-750 built-in
port)/1761-NET-
ENI

Series A,
Revision A,
FRN1

1762/1763/1764
MicroLogix

1761-NET-ENI

PLC model

EtherNet/IP

Communication unit

Firmware

version

Software used

Version of

software used

SYSMAC CJ2

-(CJ2 built-in port
or CJ1W-EIP21)

Ver. 1.0 or later

CX-One

Ver. 3.0 or later

SYSMAC CJ1

CJ1W-EIP21

Ver. 1.0 or later

SYSMAC CS1

CJ1W-EIP21

Ver. 1.0 or later

Advertising