Script file reflection timing – KEYENCE SR-750 Series User Manual

Page 25

Advertising
background image

25

E SR-750 UM

[2] Changing the script execution setting

Using the AutoID Network Navigator, set the script execution setting of the SR-
750 Series to "Enable".
This must be set for the edit data function and the edit image file name function
respectively.
[Edit data function - Script execution setting item]

[Edit image file name function - Script execution setting item]

[3] Transferring the script file
Transfer the script file (FmtSet.lua) to the SR-D100 Series.
Following are the transfer methods.
• Sending configuration of AutoID Network Navigator
• Transferring only the script file from the AutoID Network Navigator terminal
• Transferring using the Fileview software
• Transferring using the FTP

Important

When transferring the script file using the Fileview software or the
FTP, set the file name to "FmtSet.Lua".

Script file reflection timing

Even if the script file is in operation, transfer is possible each time by using the FTP.
In this case, the reflection timing of the script program is from the timing ON after
file transfer.

„

Timing chart

A

A

A

B

B

Timing input

Script file
transfer

Data
Image file name

Handing of the script file when settings are changed, etc.

This section describes how to handles the script file when restoring to the default
settings or using the changeover function.

When executing the script file - status confirmation command

„

Obtaining the script processing time

Send command

SCPTIME

Response

OK, SCPTIME, now=AAus, max=BBus, min=CCus

AA: Returns the most recent script processing time.
BB: Returns the maximum value of the processing time.
CC: Returns the minimum value of the processing time.

• Returns the processing time of script executed after power ON.

„

Script debug setting

Send command

SCPDBG, n

Response

OK, SCPDBG

n= 0: Script debug OFF
n=1: Script debug ON

• This sets whether to output debug from the script file to the command port or

not.

• Setting the debug ON executes print(str) and outputs data.

„

Obtaining the script error results

Send command

SCPERR

Response

OK, SCPERR, mmmmmmmmmmmmmmmmmmmmmmmmmmmmmm
mm… : Script error character string

• This returns the details of script error.

„

Obtaining the script version

Send command

SCPVER

Response

OK, SCPVER, mmmm, nnnn

mm...: Script library version
nn… : FmtSet.lua version

(Only when FmtSet.lua exists and the version is defined)

• FmtSet.Lua version is the value stored in variable name "SCPVERSION"

within the FmtSet.Lua file.

• This returns the script library version and the FmtSet.lua version.
• If the script library does not exist, the error code 12 is returned.
* The script library is a library file to use the edit data function and the edit image

file name function.

Operation contents

FmtSet.lua

AutoID Network Navigator "Retrieve

Configuration"

Receives with the configuration file at the

same time.

AutoID Network Navigator "Send

Configuration"

Sends with the configuration file at the same

time.

AutoID Network Navigator "Default Settings"

Remains.

Send or delete by FileView

Transmission and deletion possible from PC.

Reading quick setup codes

Remains.

Send

command

SAVE

Remains.

LOAD

Remains.

DFLT

Remains.

Advertising