Symbology tab, Details of the tuning history screen, The [manual] screen – KEYENCE SR-750 Series User Manual

Page 36

Advertising
background image

36

E SR-750 UM

Symbology tab

„

Code setting

(5) : Symbology

Specify the code type for tuning.

(6) : Code-specific setting

Set the read length and detailed conditions
of each code.
For read length and detailed conditions,
refer to [Code] tab (Page 38).

„

Parameter Bank Display Window

• Alternate

… Displays whether to use the alternate function.

When Alternate is set to "Disable", the corresponding
parameter bank will not be used.

• Code type

… Code type to perform reading. 1 code type for each bank is

displayed.

• Exposure (

μs) … Sets the exposure time to scan an image.

• Gain

… Amplifies the brightness of the scanned data.

• Dynamic range … Displays the dynamic range for scanning.
• Filter

… Displays the filter type for scanning.

• Filter count

… Displays the number of filtering times.

„

Reading State Window (During Calibration)

(1) : Level

Displays the matching level.

(2) : Brightness

Divided in 128 comprehensive
image brightness phases
according to the factors such as
dynamic range, gain and
exposure.

• Plot colors, when filtering function is activated

„

Reading State Window (Reading Rate)

• Parameter bank … Displays the bank

number used for reading.

• Reading test

… Displays a reading rate.

• Matching level … Displays a matching

level.

• Read Data

… Displays data when the

reading was successful.

„

Reading State Window (Tact Test)

• Bank number … Displays the bank number

used for reading.

• Read time

… Displays the latest read

time.

• Max time

… Displays the maximum

read time.

• Min time

… Displays the minimum read

time.

• Read Data

… Displays data when the

reading was successful.

Color

Filter name

Color code (RGB)

●: Black

Disable

0,0,0

: Yellow-green Equalize

68,192,0

: Green

Expand

0,130,58

: Light blue

Shrink

0,183,238

: Blue

Open

0,67,238

: Purple

Close

171,0,242

: Orange

Unsharp Mask 255,138,0

(5)

(6)

(1)

(2)

Details of the Tuning History screen

Click

button to display the following screen.

It is possible to select what is considered the optimal calibration results when
carrying out multiple calibrations for the same code, and register these in the
parameter bank.

• History

Displays a maximum of 8 results of calibration.
The latest calibration results are displayed at the top in position (1).
Multiple history data results can be combined and displayed on a calibration
results chart.

• Update

A button to reflect the calibration results selected in the history in the parameter
bank selected in the reading settings.

• Clear

Deletes all collected calibration history.

• Reading settings

Use the bank update button to select the parameter bank No. to update.
You can also confirm detailed values for updated calibration results.

• Tuning image

Displays image obtained at calibration, when selected in the history.

• Tuning result

Displays graphs from calibration, when selected in the history.

The [Manual] screen

Click the [Manual] button to list items that can be configured in the SR-750 Series
parameter bank.
Use this to check result values obtained in the [Auto] screen, and to manually
change parameters.

Advertising