E SR-750 UM

Edit data

(1) Additional Information

Checking the checkbox of data to add can set the Additional Information.
Default

: None for all items

(2) Read Data Format

Displays the position of added data when the Additional Information is set.

(3) Edit Data

Check "Use script" when using the edit data function.

[I/O] tab

Set operations for input/output terminals. These can be set or changed in the
[Table] tab.

„

Input Terminal

Set the operation of the input terminals (IN1 and IN2).
(1) Input Polarity

Specify the polarity of the input terminal.

Default

: Norm. open

Setting range : Norm. open (normally open) or Norm. close (normally closed)

(2) Required Input Duration

Set the time delay before the input terminal turns on.

Default

: 1 ms

Setting range : 1 ms, 2 ms, 10 ms

(3) IN1, IN2 Function

• Function

IN1 default

: TIMING

IN2 default

: PRESET

Settings range : TIMING, Preset Input, TEST, Clear PLC link error, TUNING,

Disable

• Test mode

When you select "TEST", specify the test mode desired.
Settings range : reading rate test, processing time test, position test

• Power-ON trigger

Select this to activate IN1 and IN2 specified at power-on.

(1)

(2)

(3)

(1)

(2)

(4)

(3)

(5)

„

Output terminal

Set the functions of the output terminals (OUT1, OUT2, OUT3).
(4) OUT1, OUT2, OUT3 terminal functions

• Terminal function

OUT1 default : OK
OUT2 default : NG+ERROR
OUT3 default : TRG BUSY, LOCK BUSY, MODE BUSY, ERR BUSY
Setting range : OK, NG, ERROR, STABLE, UNSTABLE, PRESET OK,

TUNING OK, TRG BUSY, LOCK BUSY, MODE BUSY, ERR
BUSY
EXT. LIGHT

EXT. LIGHT

Select to use external lighting.
Select this to make the [EXT. LIGHT] button active.

(5) • Output Duration

Specify the polarity of the output terminal. (Common between terminals)
Default

: 500 ms

Setting range : 0 to 2550 ms (Specify in units of 10 ms)

• TRG BUSY at Power-On

Specify start-up options when TRG BUSY is set.
Default

: Disable

Setting range : Disable, Enable

Refer to

"3-6 Multi-I/O Function (Page 14)"

[Saving Images] tab

Set functions for saving images. These can be set or changed in the [Table] tab.

„

Image saving function settings

Set image saving functions and modes.
(1) Saving images operations

Default

OK Image

: Disable

NG Image

: Disable

Error Image

: Save to RAM

Unstable image

: Disable

Captured Image : Save to RAM

Setting range OK Image/NG Image/Unstable image

: Disable, Send by FTP

Error Image

: Disable, Save to RAM, Save to ROM,

Send by FTP

Captured Image : Save to ROM, Send by FTP

If burst read mode is set as the operating mode, specify the burst number for
the target images.

NOTICE

You cannot set the result outputs (OK, NG, ERROR, PRESET OK,
TUNING OK), and the operation outputs (TRG BUSY, LOCK BUSY,
MODE BUSY, ERR BUSY) to the same output terminal.

• External lighting output polarity

Default

: Norm. open

Setting range : Norm. open (normally

open) or Norm. close
(normally closed)

(2)

(4)

(3)

(1)